Home/NRIAG Journal of Astronomy and Geophysics/Article Record
Peer-Reviewed Article June 26, 2017

Groundwater vulnerability assessment using hydrogeologic and geoelectric layer susceptibility indexing at Igbara Oke, Southwestern Nigeria

Are you an author of this work?Link to your sovereign AfriScholar profile
Published in: NRIAG Journal of Astronomy and Geophysics
Publisher: Taylor & Francis • Egypt • 2090-9977
DOI: https://doi.org/10.1016/j.nrjag.2017.04.009

Abstract

Groundwater vulnerability assessment was carried out at Igbara Oke Southwestern Nigeria, with a view to classify the area into vulnerability zones, by applying the electrical resistivity method, using Schlumberger electrode arrays with maximum electrode separation (AB/2) of 65 m in (41) different locations for data acquisition. Geoelectric parameters (layer resistivity and thickness) were determined from the interpreted data. The study area comprises four geoelectric layers (topsoil, lateritic layer, weathered/fractured layer and fresh basement). The geoelectric parameters of the overlying layers across the area were used to assess the vulnerability of the underlying aquifers to near-surface contaminants with the aid of vulnerability maps generated. Three models were compared by maps using geo-electrically derived models; longitudinal conductance, GOD (groundwater occurrence, overlying lithology and depth to the aquifer) and GLSI (geoelectric layer susceptibility indexing). The total longitudinal conductance map shows the north central part of the study area as a weakly protected (0.1–0.19) area, while the northern and southern parts have poor protective capacity (<0.1); this is in agreement with the GOD method which shows the northern part of the study area as less vulnerable (0–0.1) while the southern part has low/moderate (0.1–0.3) vulnerability to contamination. The longitudinal conductance exaggerates the degree of susceptibility to contamination than the GOD and GLSI models. From the models, vulnerability to contamination can be considered higher at the southern part than the northern part and therefore, sources of contamination like septic tank, refuse dump should be cited far from groundwater development area.

Download Full Text PDFView at PublisherCrossref RecordCrossref XML

Verified Citation Velocity

Recorded scholarly citations in African and international peer-reviewed literature

70
Total Citations

Citations are continuously tracked and harvested across continental OJS endpoints and OpenAlex feeds.