Home/Bulletin of the Chemical Society of Ethiopia/Article Record
Peer-Reviewed Article April 29, 2007

Voltammetric determination of chloramphenicol at electrochemically pretreated glassy carbon electrode

Are you an author of this work?Link to your sovereign AfriScholar profile
Published in: Bulletin of the Chemical Society of Ethiopia
Publisher: Chemical Society of Ethiopia • Ethiopia • 1011-3924 • 1726-801X
DOI: https://doi.org/10.4314/bcse.v21i1.61361

Abstract

A sensitive square wave voltammetric method for the determination of chloramphenicol (CAP) was developed using electrochemically pretreated glassy carbon electrode (EPGCE). Electrochemical pretreatment of the electrode greatly enhanced the reduction peak current (Ip) of CAP. The electrochemical investigation of CAP was carried out by using cyclic and square wave voltammetry techniques. CAP shows an irreversible reduction peak at -0.646 V vs. Ag/AgCl at the EPGCE in 0.05 M CH3COONa/CH3COOH buffer of pH 5.3 using the cyclic voltammetric mode. Detailed experiments were carried out to establish the electrochemical property, the optimal pH, electrode pretreatment potential and square wave voltammetric parameters. Following optimization of the instrumental parameters and pH of buffer solutions, the peak current response for the reduction of CAP was observed showing a linear calibration curve in the concentration range of 1.0 x 10-7 - 7.0 x 10-5 M CAP. Over this concentration range, two good linear ranges were obtained between the voltammetric current and CAP concentration. The first was in the linear range 1.0 x 10-7 - 5 x 10-6 M CAP (r = 0.999) and the second in the linear range 5.00 x 10-6 – 7.00 x 10-5 M CAP (r = 0.999). For a series of six determinations of CAP at 1.00 x 10-5 M and 5.00 x 10-7 M levels relative standard deviations of 2.2 % and 3.7 %, respectively were obtained, showing an excellent reproducibility of the EPGCE. When the signal to noise ratio is 3, the detection limit was 6.0 x 10-9 M. The experiment on the possible interfering substances showed that the electrode has excellent selectivity for the detection of CAP. The method was verified by the determination of CAP in eye drops. KEY WORDS: Chloramphenicol, Electrochemically pretreated glassy carbon electrode, Square wave voltammetry Bull. Chem. Soc. Ethiop. 2007, 21(1), 1-12.

Download Full Text PDFView at PublisherCrossref RecordCrossref XML

Verified Citation Velocity

Recorded scholarly citations in African and international peer-reviewed literature

35
Total Citations

Citations are continuously tracked and harvested across continental OJS endpoints and OpenAlex feeds.